It is an “Oh no!” moment when you approach your home’s thermostat and see its screen is blank.
Is it serious? Does it mean your furnace, heat pump, or air conditioning is broken? Not necessarily. In fact, most of the time, it is something minor and can be easily fixed.
Here are some of the most frequent reasons our MLD Services, LLC professionals see a thermostat blank screen here in the Georgetown area:
If your thermostat wall does not have a c-wire, or common wire, your thermostat is most likely not hooked up to your heating, ventilation, and air conditioning (HVAC) system for its power and requires batteries. When your screen is blank, it could indicate you need to replace the batteries.
If this is the case, you typically need AA alkaline or 3-volt lithium batteries, so check what type is currently powering the thermostat and simply replace them. Most thermostats display a low-battery symbol when the juice is running low.
Chill Out
On the other hand, if your thermostat is hardwired to your HVAC system for power, it could be a temporary blank screen if the thermostat is in the middle of recharging. Wait a short time and see if the display returns. If it does not, read on.
Dead batteries.
Sometimes the wires hooked up to your thermostat are responsible for its lack of power. If they originally were not firmly attached or the thermostat is in a high-traffic room, the vibrations from people walking by can actually affect the wires.
Loose wiring or wiring problems.
Our professionals have also seen wires chewed by rodents damage the wiring. According to Humane Society International, these rodents will continue to cause havoc in your Georgetown home until you locate their entrance/exit opening and permanently seal it.
Tripped circuit breaker or blown fuse.
Since wiring deals directly with electricity, we recommend calling us to diagnose and repair the issue for you. When it comes to electricity, rely on a professional. It is much better to be safe than sorry.
Tripped safety switch.
A quick fix to restore your thermostat’s power is a tripped circuit breaker or blown fuse, depending what you have in your Texas home. Sometimes a surge can cause this issue.
Open furnace door.
If you check your electrical box and a circuit breaker is tripped, just flip it back. If you have fuses, replace the fuse.
Old thermostat.
Once this is done, check your thermostat. If you have power again, you are set; but if the breaker trips again or the replacement fuse blows, you may have a more involved HVAC problem. You need to get one of our MLD Services, LLC professionals involved.
Call Us With Any Thermostat Concerns
HVAC systems have built-in safety switches to protect you in an unsafe situation. In the event one of your unit’s safety switch is tripped, the transformer supplying voltage to your unit (and possibly your thermostat) will stop power.